Issue No. : 1
Issue
Date : November 2010
Project
No. : 768
Joint
User Complex and Wholesale Fish Market at Area 44, Tuen
Mun
Environmental
Monitoring
& Audit Report (October 2010)
Prepared By:
Allied Environmental Consultants Ltd.
COMMERCIAL-IN-CONFIDENCE
Issue No. : 1
Issue Date : November 2010
Project No. : 768
Joint
User Complex and Wholesale Fish Market at Area 44, Tuen
Mun
Environmental
Monitoring
& Audit Report (October 2010)
Prepared By:
Allied Environmental Consultants Ltd.
COMMERCIAL-IN-CONFIDENCE
Author:
Nic H. H. Lam
BSc(Hons) AMHKIOA
Checked: Approved:
Winnie M.W. Ma Grace M. H. Kwok
BEnvMgmt(Hons) MSc AMHKIOA BEng(Hons) MHKIEIA MHKIOA
MISWA MIAIA MRAPA LEED AP
This report has been prepared by Allied Environmental Consultants Limited
with all reasonable skill, care and diligence within the terms of the Agreement
with the client, incorporating our General Terms and Conditions of Business and
taking account of the resources devoted to it by agreement with the client.
We disclaim any responsibility to the client and others in respect of any
matters outside the scope of the above.
This report is confidential to the client and we accept no responsibility
of whatsoever nature to third parties to whom this report, or any part thereof,
is made known. Any such party
relies upon the report at their own risk.
Table of Contents
Table of Contents i
List of Tables ii
List of Figures ii
List of Appendices ii
EXECUTIVE SUMMARY 1
1. PROJECT BACKGROUND 2
1.1 Project Organization and Contact Personnel 2
2. SENSITIVE RECEIVERS 3
3. CONSTRUCTION WORKS & PROGRAMME 3
4. SUMMARY OF
EM&A REQUIREMENT 4
5. MONITORING METHODOLOGY 6
5.1 Monitoring Programme 6
5.2 Air Quality Monitoring 6
5.3 Noise Monitoring 6
6. RESULTS 7
6.1. Air Quality 7
6.2. Noise 8
6.3. Weather Conditions 8
7. SITE INSPECTION
& AUDIT 9
8. Non-compliance,
Complaints, Notifications of Summons and Successful Prosecutions 9
9. OTHERS 10
10. CONCLUSIONS 10
Table
1 Contact Details of Key Personnel
Table
2 Interrelationship between
Construction Activities and Mitigation Measures
Table 3 Action and Limit Level for Air Quality Impact Monitoring at Yuet
Wu Villa
Table 4 Action and Limit Levels for Construction
Noise Impact Monitoring
Table 5 Event Action Plan
Table 6 Noise
Monitoring Equipment
Table 7 1-hour TSP Monitoring Results
Table 8 24-hour TSP Monitoring Results
Table 9 Noise Monitoring Results
Table 10 Summary
of Weather Conditions during the Monitoring Period
Table 11 Summary
of Site Inspections
Figure
1 Site
Location Plan
Figure
2 Location
of Air Quality Monitoring Station
Figure 3 Location
of Noise Monitoring Station
Figure
4 Photos
of Air Quality Monitoring Station
Figure
5 Photos
of Noise Monitoring Station
Appendix A Detail
Schedule of Monitoring Programme
Appendix B Calibration Record
of High-Volume TSP Sampler
Appendix
C Calibration
Certification of the Sound Level Meter and Calibrator
Appendix
D Summary of 1-Hour TSP Monitoring
Record
Appendix
E Summary of 24-Hour TSP Monitoring
Record
Appendix
F Summary of Noise Monitoring Record
Appendix
G Wind Record from Hong Kong Observatory
Appendix
H Mitigation Measures Implementation
Schedule for Construction Stage
Allied Environmental Consultants Limited
(AEC) has been appointed to conduct an environmental monitoring and audit
(EM&A) program for the proposed Joint User Complex and
Wholesale Fish Market at Area 44, Tuen Mun. The construction works were commenced on
Impact environmental monitoring for the proposed Joint User Complex and Wholesale Fish Market at Area
44, Tuen Mun has been carried out on 4th,
9th, 15th, 21st and 27th October 2010 at
Block 15, Yuet Wu Villa. 1-hr
TSP and noise monitoring were conducted within the period of 0700-1900 hours,
where
24-hr
TSP monitoring was conducted continuously for a 24-hour period.
1-hour TSP monitoring results at the monitoring location ranged from 78£gg/m3 to 137£gg/m3 with an average of 109£gg/m3. 24-hour TSP monitoring
results ranged from 58£gg/m3 to 76£gg/m3 with an average of 71£gg/m3.
Noise monitoring results at the monitoring
location ranged from 61.2dB(A) to 61.9dB(A)
with an average of 61.6dB(A).
Based on the monitoring results, the air
quality and construction noise level complied with the environmental
requirements in EM&A Manual. There were no breaches of the action and limit
levels.
In this reporting
period, there was no updated status from EPD regarding the use of powered mechanical equipment, for the
purpose of carrying out construction work other than percussive piling in
respect of which a construction noise permit was not in force on 16th May 2010 at Joint-User
complex and Wholesale Fish Market in Area 44, Tuen Mun, New Territories.
No other complaint,
inspection notice, notification of summons or prosecution was received.
Construction activities will be
undertaken in November 2010 include defects rectification for internal /
external finishing works, installation of signage works, carrying out of
additional finishing works, handover preparation works and installation of
additional E&M services works
Potential
environmental impacts include dust generation from stockpiles of dusty
materials and the internal finishes; noise from operation of the equipments, and the storage of various C&D
and chemical wastes. The Contractor should properly implement the required
environmental mitigation measures as per the implementation schedule in the
EM&A manual to ensure no significant adverse environmental impacts to be
arisen from the construction works. The Contractor was reminded to maintain
good housekeeping throughout the construction phase.
A Joint User
Complex and Wholesale Fish Market (WFM Complex) at Area
The subject site is located at Castle Peak
Bay of Tuen Mun given in Figure 1. The subject site is bounded to the north by a future local
open space presently used as a temporary car park, to the east by
Key personnel and contact particulars are summarized in Table 1.
Table 1 Contact
Details of Key Personnel
Role |
Department
/ Company |
Names |
Contact
Number |
Fax
Number |
Lead User
Department |
Agriculture,
Fisheries, and Conservation Department |
Mr. K.H. Chan Ms. Louise Li |
2150 7092 2150 7104 |
2314 2866 |
Environmental
Permit Holder |
Architecture
Services Department |
Mr. S.W. Chow Ms. Susana Chan |
2867 3716 2867 3706 |
2523 9622 |
Architect |
P&T
Architects and Engineers Ltd. |
Ms. Sarah Ng Ms. Vivian Law |
2835 3548 2832 3046 |
2891 3834 |
Main
Contractor |
W. Hing Construction Co. Ltd. |
Mr. Andy Chan Mr. Jim Lee |
9630 7404 6105 4076 |
8343 9188 |
Environmental
Team Leader |
Allied
Environmental Consultants Ltd. |
Ms. Grace
Kwok |
2815 7028 |
2815 5399 |
Independent
Environmental Checker |
Cinotech
Consultants Ltd. |
Dr. Priscilla Choy |
2151 2089 |
3107 1388 |
Air Sensitive Receivers (ASRs) within
Noise Sensitive Receivers (NSRs) within
The major works undertaken and/or completed during the
monitoring period are listed below:
-
Defects rectification for internal / external
finishing works;
-
Installation of additional / variation E&M
works; and
-
Preparation works for handover to end user.
Table 2 shows the interrelationship between construction activities and
environmental mitigation measures for the reporting month.
Table 2 Interrelationship
between Construction Activities and Mitigation Measures
Construction
Works |
Major
Environmental Impact |
Mitigation
Measures |
E&M
services and planting works |
Water
quality impacts |
Waste
water were reused when practicable |
Internal &
external finishes and installation works |
Noise
impacts |
Closely
monitoring of noise impacts |
For regular
impact monitoring, the sampling frequency of at least once in every six-days,
shall be strictly observed at the monitoring station for 24-hr TSP monitoring.
For 1-hr TSP monitoring, the sampling frequency of at least three times in
every six-days should be undertaken when the highest dust impact occurs. For
noise monitoring, one set of measurement between 0700-1900 hours on normal
weekdays. Leq (30 min) shall be used as the
monitoring parameter.
From baseline monitoring results, the proposed Action and Limit Levels for air quality are summarized in Table 3. The average baseline 1-hr TSP value of 129£gg/m3 and 24-hr TSP value of 65£gg/m3
measured at Block 15, Yuet Wu Villa was used to determine the action and limit
level for air quality impact monitoring. The proposed Action and Limit Levels
for construction noise are summarized in Table 4.
Table 3 Action
and Limit Level for Air Quality Impact Monitoring at Yuet Wu Villa
Parameters |
Baseline
Level (£gg/m3) |
Action
Level (£gg/m3) |
Limit
Level (£gg/m3) |
24-Hour
TSP Level |
65 |
173 |
260 |
1-Hour
TSP Level |
129 |
334 |
500 |
Table 4
Action and Limit Levels for Construction Noise Impact Monitoring
Time
Period |
Action
Level |
Limit Level |
Daytime
(0700-1900 hours) on weekdays |
When one
documented compliant is received |
Dwelling 75dB(A) 1 School 70dB(A) 1 (65dB(A) during examinations) 1 |
1900-2300
on any day and 0700-2300 on Sunday and general holidays, for use of PME2 |
When one documented
compliant is received |
65dB(A) 3 |
All days during the night-time
(2300-0700 hours) 2 |
When one documented
compliant is received |
50dB(A) 3 |
Note: 1. Construction
noise criteria stipulated in the TM-EIAO
2. A Construction
Noise Permit (CNP) shall be required for the carrying out of the construction
work during the restricted hours (1900-2300 on any day
and 0700-2300 on Sunday and general holidays, for use of PME; and All days
during the night-time (2300-0700 hours))
3. Area sensitivity rating of the monitoring location
is ¡§B¡¨.
Should non-compliance of the above Action and Limit levels occurs, the
contractor shall undertake corresponding in accordance with the proposed Event
Action Plan given in the EM&A Manual. A summarized general Event Action
Plan is given in Table 5. Details should be referred to
the Event Action Plan in the EM&A Manual.
Level |
Step 1 |
Step 2 |
Step 3 |
Action |
l Identify source l Check monitoring data and working
methods |
l Contact project manager to discuss
and implement remedial action l Rectify any unacceptable practice l Amend working methods if
appropriate l If exceedance
continues, commence additional monitoring |
l Notify client/project manager
following correct of the situation l Cease additional monitoring if exceedance stops |
Limit |
l Identify source l Notify client/project manager l Check monitoring data and working
methods l Repeat measurement to confirm
finding l Commence additional monitoring |
l Take immediate action to avoid
further exceedance l Submit proposal for remedial
actions to client/project manager within 3 working days l Implement the agreed proposal l If exceedance
continues, amend and resubmit the proposal |
l Notify client/project manager
following correction of the situation l Cease additional monitoring if exceedance stops |
Air quality monitoring and noise
monitoring were conducted at Block 15, Yuet Wu Villa on
4th, 9th, 15th, 21st and 27th
October 2010. The tentative air quality monitoring and noise
monitoring for November 2010 will be scheduled on 3rd,
9th, 15th, 20th and 26th November 2010. Appendix A displayed the detail schedule of the monitoring programme. Air
quality monitoring station was set up at the roof top of the residential block
and noise monitoring was conducted at
1-hour and 24-hour TSP air quality monitoring was conducted at the
designated air quality monitoring location using a High Volume TSP Sampler (Model No: Anderson GMWS-2310 ACCU-VOL) at the designated location. The Calibration Record of the High-Volume TSP
Sampler is given in Appendix B. 24-hour TSP samples were taken every six days. 1-hour TSP samples were taken three times a day between 0700-1900 hours. The weighing of the filter paper used in the
monitoring was undertaken by ALS Laboratory Group Environmental Division.
(HOKLAS Registration No.: 066)
Noise monitoring was conducted
at the designated noise monitoring location between 0700-1900 hours using a sound
level meter which complies with the International Electrotechnical
Commission Publications 651:1979 (Type 1) and 804:1985 (Type 1). Noise
instrumentation details are given in Table 6 and the
Calibration Certificate for the sound level meter and calibrator is given in Appendix C.
Table 6 Noise
Monitoring Equipment
Manufacturer |
Type/Model
No. |
Equipment |
RION |
Model NL
31 |
Precision
Sound Level Analyser with windshield |
RION |
|
Calibrator |
AZ
Instrument |
AZ Instrument 8908 |
Thermo-anemometer |
Noise level measurements
were recorded in terms of thirty minutes A-weighted equivalent continuous sound
pressure level (Leq(30min)) on a
daily basis. The sound level meter was calibrated immediately prior to and
following each noise measurement. The meter was mounted on a tripod at a height
of
Noise measurements were not made in the presence of fog, rain, and wind
with a steady speed exceeding
1-hour and 24-hour TSP monitoring results are
summarized in Tables 7 and 8 and
serve as the basis for determining the action and limit levels. The minimum and
maximum 1-hour TSP measured at Yuet Wu Villa was 78£gg/m3 and 137£gg/m3 respectively with an average of 109£gg/m3. The minimum and maximum 24-hour TSP measured was 58£gg/m3 and 76£gg/m3 respectively
with an average of 71£gg/m3. Summary of air quality
monitoring record is provided in Appendices D and E.
Table 7 1-Hour
TSP Monitoring Results
Date |
1-hr TSP (£gg/m3) |
Average (£gg/m3) |
|||
Reading 1 |
Reading 2 |
Reading 3 |
Average |
||
4th October 2010 |
111 |
93 |
114 |
106 |
109 |
9th October 2010 |
102 |
78 |
99 |
93 |
|
15th October 2010 |
83 |
99 |
113 |
98 |
|
21st October 2010 |
131 |
114 |
113 |
119 |
|
27th October 2010 |
137 |
122 |
123 |
127 |
Table 8 24-Hour
TSP Monitoring Results
Date |
24-hr TSP (£gg/m3) |
4th October 2010 |
76 |
9th October 2010 |
73 |
15th October 2010 |
58 |
21st October 2010 |
73 |
27th October 2010 |
73 |
Average |
71 |
Noise monitoring results in terms of Leq(30min),
L10(30min) L90(30min) measured at the designated noise
monitoring location are summarized in Table 9. L10(30min) and L90(30min) represent
sound levels that are exceeded 10% and 90% of the time respectively. Normally, L10(30min) measurements
can be considered as the average peak levels, whilst L90(30min)
levels can be considered as the average background noise levels.
During the reporting month, the minimum and maximum noise level measured at Yuet Wu Villa was 61.2dB(A) Leq(30min)
and 61.9dB(A)
Leq(30min) respectively with an average of 61.6dB(A) Leq(30min).
No exceedance was recorded in this reporting
period. Summary of noise monitoring
record will be provided in Appendix F.
Table 9 Noise
Monitoring Results
Date |
L10(30mins) (dB(A)) |
L90(30mins) (dB(A)) |
Leq (30mins) (dB(A)) |
4th October 2010 |
63.9 |
58.6 |
61.2 |
9th October 2010 |
63.9 |
58.7 |
61.7 |
15th October 2010 |
63.7 |
58.7 |
61.9 |
21st October 2010 |
63.9 |
58.9 |
61.7 |
27th October 2010 |
62.9 |
58.6 |
61.7 |
Average |
63.7 |
58.7 |
61.6 |
Weather data of the monitoring station were obtained from the nearest
Hong Kong Observatory (HKO) Tuen Mun
automatic weather station located at Tuen Mun Town Park (63 mPD). Table
10 summarizes the wind data during the monitoring dates. Wind record from HKO is shown in Appendix G.
Table 10 Summary of
Weather Conditions during the Monitoring Period
Date |
Weather |
Prevailing
Wind direction |
Daily Average
Wind speed (m/s) |
4th October 2010 |
Cloudy |
NE |
3.55 |
9th October 2010 |
Cloudy |
N |
1.52 |
15th October 2010 |
Cloudy |
NE |
3.61 |
21st October 2010 |
Cloudy |
N |
3.36 |
27th October 2010 |
Sunny |
NE |
4.27 |
4 site
inspections were conducted by the Environmental Team (ET) in this reporting period.
Major observations by the ET, actions by the Contractor and outcome are
summarized in the Table 11.
Table 11 Summary
of Site Inspections
Date |
Observations |
Action
taken by Contractor |
Outcome |
8th October 2010 |
No observations during inspection. |
Contractor was required to keep up with the mitigation
measures. |
Nil. |
15th October 2010 |
No observations during inspection. |
Contractor was required to keep up with the
mitigation measures. |
Nil. |
22nd October 2010 |
No observations during inspection. |
Contractor was required to keep up with the
mitigation measures. |
Nil. |
29th October 2010 |
No observations during inspection. |
Contractor was required to keep up with the
mitigation measures. |
Nil. |
During site inspections in the reporting month, no non-conformance of implementation
of environmental mitigation measures was identified. All environmental mitigation measures for construction
stages stated in approved EIA Report, EM&A Manual and Environmental Permit
shall be carried out throughout the whole construction period as shown in Appendix H.
In this reporting period, there was no updated
status from EPD regarding the use of powered mechanical equipment, for the
purpose of carrying out construction work other than percussive piling in
respect of which a construction noise permit was not in force on 16th May 2010 at Joint-User
complex and Wholesale Fish Market in Area 44, Tuen Mun, New Territories.
No other complaint, inspection notice,
notification of summons or prosecution was received.
In the reporting month, no inert
C&D material was disposed of at public fill. A total of 18.77 tonnes of
waste including general refuse and non-inert C&D wastes such as timber and
bamboo were disposed to landfill. No chemical waste was transported off site in
this reporting period.
Environmental monitoring
has been carried out for the proposed Joint User Complex and Wholesale Fish Market at Area 44, Tuen Mun. 1-hour and 24-hour
TSP air quality monitoring and noise monitoring was conducted at Block 15, Yuet
Wu Villa during the period from 1st October 2010 to 31st October 2010.
The average 1-hour
TSP level is 109£gg/m3 and average 24-hour TSP level is 71£gg/m3. For impact noise monitoring, the average Leq(30min)
is 61.6dB(A). All monitoring
results complied with the relevant action and limit levels.
In this reporting period, there was no updated
status from EPD regarding the use of powered mechanical equipment, for the
purpose of carrying out construction work other than percussive piling in
respect of which a construction noise permit was not in force on 16th May 2010 at Joint-User
complex and Wholesale Fish Market in Area 44, Tuen Mun, New Territories.
No other complaint, inspection notice,